{"id":1321,"date":"2023-11-19T11:50:41","date_gmt":"2023-11-19T10:50:41","guid":{"rendered":"http:\/\/domotics.fr\/?p=1321"},"modified":"2023-11-19T11:50:41","modified_gmt":"2023-11-19T10:50:41","slug":"ac-sensor-1pcs-current-sct-013-030-clamp-30a-non-invasive","status":"publish","type":"post","link":"https:\/\/domotics.fr\/index.php\/2023\/11\/19\/ac-sensor-1pcs-current-sct-013-030-clamp-30a-non-invasive\/","title":{"rendered":"Ac Sensor 1Pcs Current SCT-013-030 Clamp 30A Non-Invasive"},"content":{"rendered":"<div id=\"pl-1321\" class=\"panel-layout\">\n<div id=\"pg-1321-0\" class=\"panel-grid panel-no-style\">\n<div id=\"pgc-1321-0-0\" class=\"panel-grid-cell\" data-weight=\"1\">\n<div id=\"panel-1321-0-0-0\" class=\"so-panel widget widget_sow-editor panel-first-child panel-last-child\" data-index=\"0\">\n<div class=\"so-widget-sow-editor so-widget-sow-editor-base\">\n<div class=\"siteorigin-widget-tinymce textwidget\">\n<p>Ac Sensor 1Pcs Current SCT-013-030 Clamp 30A Non-Invasive<\/p>\n<div class=\"tlid-input input\">\n<div class=\"source-wrap\">\n<div class=\"input-full-height-wrapper tlid-input-full-height-wrapper\">\n<div class=\"source-input\">\n<div class=\"source-footer-wrap source-or-target-footer\">\n<div class=\"source-footer\">\n<div class=\"speech-wrap source-or-target-footer-button left-positioned\">\n<div id=\"gt-speech\" class=\"speech-button goog-toolbar-button goog-toolbar-button-disabled\" role=\"button\" aria-label=\"S\u00e9lectionnez une langue sp\u00e9cifique pour activer la saisie vocale\" data-tooltip-align=\"t,c\" aria-pressed=\"false\" aria-disabled=\"true\" data-tooltip=\"S\u00e9lectionnez une langue sp\u00e9cifique pour activer la saisie vocale\"><\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<div class=\"tlid-results-container results-container\">\n<div class=\"tlid-result result-dict-wrapper\">\n<div class=\"result tlid-copy-target\">\n<div class=\"result-header\">\n<div class=\"starbutton jfk-button-flat jfk-button unstarred\" tabindex=\"0\" role=\"button\" aria-label=\"Activer le suivi de la traduction\" data-tooltip=\"Activer le suivi de la traduction\" data-tooltip-align=\"t,c\">\n<div class=\"jfk-button-img\"><\/div>\n<\/div>\n<\/div>\n<div class=\"text-wrap tlid-copy-target\">\n<div class=\"result-shield-container tlid-copy-target\"><span class=\"tlid-translation translation\"><span class=\"tlid-translation translation\">Les transformateurs de courant (CT) sont des capteurs qui mesurent le courant alternatif (AC). Ils sont particuli\u00e8rement utiles pour mesurer la consommation ou la production d&rsquo;\u00e9lectricit\u00e9 d&rsquo;un b\u00e2timent entier.<\/span><\/span><\/p>\n<p>Le type \u00e0 noyau divis\u00e9, tel que le CT dans l&rsquo;image ci-dessus, peut \u00eatre clips\u00e9 sur le fil sous tension ou neutre venant dans le b\u00e2timent, sans qu&rsquo;il soit n\u00e9cessaire d&rsquo;effectuer des travaux \u00e9lectriques \u00e0 haute tension.<\/p>\n<p>Comme tout autre transformateur, un transformateur de courant comporte un enroulement primaire, un noyau magn\u00e9tique et un enroulement secondaire.<\/p>\n<p>Dans le cas de la surveillance de l&rsquo;ensemble du b\u00e2timent, l&rsquo;enroulement principal est le fil sous tension ou neutre (PAS les deux!) Qui p\u00e9n\u00e8tre dans le b\u00e2timent et qui passe dans l&rsquo;ouverture du TC. L&rsquo;enroulement secondaire est constitu\u00e9 de nombreuses spires de fil fin log\u00e9es dans le bo\u00eetier du transformateur.<\/p>\n<p>Le courant alternatif circulant dans le primaire produit un champ magn\u00e9tique dans le noyau, qui induit un courant dans le circuit d&rsquo;enroulement secondaire [1].<\/p>\n<p>Le courant dans l&rsquo;enroulement secondaire est proportionnel au courant dans l&rsquo;enroulement primaire:1001\/5000<\/p>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-medium wp-image-1322\" src=\"https:\/\/domotics.fr\/wp-content\/uploads\/2019\/01\/Pince_ampermetrique_ESP8266-300x281.jpg\" alt=\"\" width=\"300\" height=\"281\" srcset=\"https:\/\/domotics.fr\/wp-content\/uploads\/2019\/01\/Pince_ampermetrique_ESP8266-300x281.jpg 300w, https:\/\/domotics.fr\/wp-content\/uploads\/2019\/01\/Pince_ampermetrique_ESP8266.jpg 601w\" sizes=\"auto, (max-width: 300px) 100vw, 300px\" \/><\/p>\n<table class=\"STYLE_CONTEXT_NORMAL\" border=\"1\" width=\"600\" cellspacing=\"0\" align=\"center\">\n<tbody>\n<tr>\n<td>Product Name<\/td>\n<td>Non-invasive AC Current Sensor<\/td>\n<\/tr>\n<tr>\n<td>Model<\/td>\n<td>SCT-013-030<\/td>\n<\/tr>\n<tr>\n<td>Core Material<\/td>\n<td>Ferrite<\/td>\n<\/tr>\n<tr>\n<td>External Material<\/td>\n<td>Plastic<\/td>\n<\/tr>\n<tr>\n<td>Input Current<\/td>\n<td>0-30A<\/td>\n<\/tr>\n<tr>\n<td>Output Mode<\/td>\n<td>Current\/33mA<\/td>\n<\/tr>\n<tr>\n<td>Opening Size<\/td>\n<td>13 x 13mm\/ 0.5&Prime; x 0.5&Prime;(L*W)<\/td>\n<\/tr>\n<tr>\n<td>Output Plug<\/td>\n<td>3.5mm<\/td>\n<\/tr>\n<tr>\n<td>Dielectric Strength<\/td>\n<td>6000V AC\/1min<\/td>\n<\/tr>\n<tr>\n<td>Working Temperature<\/td>\n<td>-25-70\u00b0C<\/td>\n<\/tr>\n<tr>\n<td>Cable Length<\/td>\n<td>1.18m\/ 45.4&Prime;<\/td>\n<\/tr>\n<tr>\n<td>Weight<\/td>\n<td>63g<\/td>\n<\/tr>\n<tr>\n<td>Package Content<\/td>\n<td>1 x Non-invasive AC Current Sensor<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p><strong>What is CT sensors<\/strong><\/p>\n<p>Current transformers (CTs) are sensors that are used for measuring alternating current. They are particularly useful for measuring whole building electricity consumption (or generation for that matter).<\/p>\n<p>The split core type such as the CT in the picture above, is particularly suitable for DIY use it can be clipped straight on to either the live or neutral wire coming into the building without having to do any high voltage electrical work.<\/p>\n<p><strong>Applications<\/strong><\/p>\n<ul class=\" list-paddingleft-2\">\n<li>Suitable for the current measuring<\/li>\n<li>Monitoring and protection of AC motor<\/li>\n<li>Lighting equipment<\/li>\n<li>Air compressor<\/li>\n<\/ul>\n<p><strong>Specifications<\/strong><\/p>\n<ul class=\" list-paddingleft-2\">\n<li>Input Current: 0~30A AC<\/li>\n<li>Output Mode: DC 0~1V<\/li>\n<li>Non-linearity\uff1a2-3%<\/li>\n<li>Build-in sampling resistance\uff08RL): 62&amp;Omega;<\/li>\n<li>Turn Ratio: 1800:1<\/li>\n<li>Resistance Grade: Grade B<\/li>\n<li>Work Temperature: -25&amp;deg;C ~ \ufe6270&amp;deg;C<\/li>\n<li>Dielectric Strength(between shell and output): 1000V AC\/1min 5mA<\/li>\n<li>Leading Wire in Length: 1m<\/li>\n<li>Open Size: 13mm x 13mm<\/li>\n<\/ul>\n<p>https:\/\/learn.openenergymonitor.org\/electricity-monitoring\/ct-sensors\/introduction?redirected=true<\/p>\n<p>https:\/\/learn.openenergymonitor.org\/electricity-monitoring\/ct-sensors\/interface-with-arduino?redirected=true<\/p>\n<p>https:\/\/learn.openenergymonitor.org\/electricity-monitoring\/ct-sensors\/how-to-build-an-arduino-energy-monitor-measuring-current-only?redirected=true<\/p>\n<\/div>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-medium wp-image-1325\" src=\"https:\/\/domotics.fr\/wp-content\/uploads\/2019\/01\/pince_ampermetrique_caution-300x109.png\" alt=\"\" width=\"300\" height=\"109\" srcset=\"https:\/\/domotics.fr\/wp-content\/uploads\/2019\/01\/pince_ampermetrique_caution-300x109.png 300w, https:\/\/domotics.fr\/wp-content\/uploads\/2019\/01\/pince_ampermetrique_caution.png 608w\" sizes=\"auto, (max-width: 300px) 100vw, 300px\" \/><\/p>\n<p>https:\/\/www.thingiverse.com\/thing:3169243<\/p>\n<div class=\"thing-info\">\n<div id=\"description\" class=\"thing-info-content rendered-markdown\">\n<div>\n<p>eBay\u00a0<a href=\"https:\/\/www.ebay.co.uk\/itm\/132830213834\" rel=\"nofollow\">https:\/\/www.ebay.co.uk\/itm\/132830213834<\/a><\/p>\n<p>More info at\u00a0<a href=\"https:\/\/www.mottramlabs.com\/products.html\" rel=\"nofollow\">https:\/\/www.mottramlabs.com\/products.html<\/a><\/p>\n<p>Firmware and PCB\u00a0<a href=\"https:\/\/github.com\/Mottramlabs\/MQTT-Power-Sensor\" rel=\"nofollow\">https:\/\/github.com\/Mottramlabs\/MQTT-Power-Sensor<\/a><\/p>\n<\/div>\n<\/div>\n<\/div>\n<div class=\"content-box full-width\">\n<div>\n<div><\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n","protected":false},"excerpt":{"rendered":"<p>Ac Sensor 1Pcs Current SCT-013-030 Clamp 30A Non-Invasive Les transformateurs de courant (CT) sont des capteurs qui mesurent le courant alternatif (AC). Ils sont particuli\u00e8rement utiles pour mesurer la consommation ou la production d&rsquo;\u00e9lectricit\u00e9 d&rsquo;un b\u00e2timent entier. Le type \u00e0 noyau divis\u00e9, tel que le CT dans l&rsquo;image ci-dessus, peut \u00eatre clips\u00e9 sur le fil [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":0,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[1],"tags":[],"class_list":["post-1321","post","type-post","status-publish","format-standard","hentry","category-non-classe","entry"],"_links":{"self":[{"href":"https:\/\/domotics.fr\/index.php\/wp-json\/wp\/v2\/posts\/1321","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/domotics.fr\/index.php\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/domotics.fr\/index.php\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/domotics.fr\/index.php\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/domotics.fr\/index.php\/wp-json\/wp\/v2\/comments?post=1321"}],"version-history":[{"count":1,"href":"https:\/\/domotics.fr\/index.php\/wp-json\/wp\/v2\/posts\/1321\/revisions"}],"predecessor-version":[{"id":2489,"href":"https:\/\/domotics.fr\/index.php\/wp-json\/wp\/v2\/posts\/1321\/revisions\/2489"}],"wp:attachment":[{"href":"https:\/\/domotics.fr\/index.php\/wp-json\/wp\/v2\/media?parent=1321"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/domotics.fr\/index.php\/wp-json\/wp\/v2\/categories?post=1321"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/domotics.fr\/index.php\/wp-json\/wp\/v2\/tags?post=1321"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}